Skip to main content

Tibia Force

Description​

Tibia Force reports peak axial compression at an upper or lower left/right tibia load cell. It compares the peak with the ATD's available reference value and reports THOR AIS 2+ risk when applicable [1] [2].

When this feature is available​

Tibia Force becomes available when either the current curve selection or any loaded test contains a tibia measurement set that meets the requirements. Only channels with a usable data status count.

The required measurement set includes:

  • The signal attachment must be an upper or lower tibia location, such as TIBIA - LEFT UPPER, TIBIA - RIGHT UPPER, TIBIA - LEFT LOWER, or TIBIA - RIGHT LOWER.
  • The group must contain a force channel with:
    • Axis: Z - LOCAL
    • Units: NEWTONS

WebSAT checks each tibia attachment independently and enables Tibia Force if any supported left- or right-side measurement set contains the required channel.

Settings​

This feature has no settings.

How WebSAT processes the data​

  1. Validate the Z-force channel at the supported tibia attachment.
  2. Convert the force signal to newtons.
  3. Filter the signal at CFC 600.
  4. Trim pre-zero data when it is present.
  5. Apply the expected compression polarity.
  6. Find the peak compressive force and its time.
  7. Use the attachment to select the upper- or lower-tibia IARV and THOR risk relationship.
  8. Report the peak, percent of IARV, and available injury risk.

Reference values and injury risk​

The Hybrid III values follow the published ATD IARVs; THOR and THOR-LX values follow the corresponding THOR injury-criteria definitions [1] [2].

ATDUpper tibia IARV (N)Lower tibia IARV (N)
Hybrid III 95th male-9820-9820
Hybrid III 50th male-8000-8000
Hybrid III 5th female-5100-5100
THOR 50th male-7011-8017
THOR 5th female-4000-3800
Hybrid III 50th male with THOR-LX legs-5577-5861
Hybrid III 5th female with THOR-LX legs-4000-3800

A negative sign denotes compression in the ATD coordinate convention. WebSAT compares force magnitudes when calculating percent of IARV. SID-IIs does not have a tibia-force IARV in the available ATD reference data.

For THOR results, WebSAT uses the peak compressive force in kilonewtons to calculate AIS 2+ probability. It uses separate relationships for the upper and lower tibia [2]:

P(AIS 2+∣upper)=11+e5.7415−0.8189FupperP(AIS\,2+\mid\text{upper})=\frac{1}{1+e^{5.7415-0.8189F_{upper}}}

P(AIS 2+∣lower)=11+e3.7544−0.4683FlowerP(AIS\,2+\mid\text{lower})=\frac{1}{1+e^{3.7544-0.4683F_{lower}}}

Other supported ATDs receive IARV and percent-IARV output without a tibia-force probability.

Results​

The summary reports test, occupant, tibia attachment, peak compression, peak time, IARV, percent of IARV, and THOR AIS 2+ probability when available. A time-history plot shows the processed force and governing peak.

WebSAT tibia-force summary table for test 10099
Tibia-force summary for the available upper- and lower-tibia measurements from both front-seat occupants in test 10099.
WebSAT tibia-force graph
Filtered axial tibia-force history for the selected occupant and attachment.

References​

[1] Mertz, H. J., Irwin, A. L., and Prasad, P. “Biomechanical and Scaling Bases for Frontal and Side Impact Injury Assessment Reference Values.” Stapp Car Crash Journal, 47, 2003, pp. 155–188. SAE Technical Paper 2003-22-0009.

[2] Craig, M. et al. Injury Criteria for the THOR 50th Male ATD. National Highway Traffic Safety Administration, 2020.